    Digital Pressure Control Switch WPC-10 Digital Display WPC 10 Eletronic Pressure Controller for Water Pump With G1/2"Adapter
    Technical Parameter:
    Pressure Range
    0-10KG/CM2
    Voltage Supply
    220Vac(You require a 3 phase AC contactor with 380V pump)
    Technical Parameter:
    Pressure Range
    0-10KG/CM2
    Voltage Supply
    220Vac(You require a 3 phase AC contactor with 380V pump)
    Connection
    G1/2(Standard),it also can be customized
    Overload Capacity
    220V,10A; Pump(≤1.5KW)
    can be started directly
    Product Feature:
    environment-friendly:silent design
    Safe: IP65,water-proof case,water-shortage protection
    Intelligent: Preventing the pump automatically restart frequently
    Reliable: Electronic Design, long-life for using, more than 200,000 times operation,anti-vibration
    Widely application:Pipeline Pump,Booster Pump,Self-priming pump,Immersible Pump,Circulating Pump ect.,widely using for solar heat pump,air-source heat pump,WILO home booster pump,Grundfos hot water circulating pump and other relevant pumps.
    Description of Using:
    Water Supply from Upstairs to Downstairs
    Pressure relief valve
    The position of device
    Height
    the lowest outlet of water
    The Upper Value=The Max. Pressure of Pump -0.5KG
    The lower value=0.5KG
    Water shortage protection value=0.2KG
    Water Supply from Downstairs to Upstairs:
    the highest outlet of water
    The Upper Value=The Max. Pressure of Pump -0.5KG
    The lower value=H*0.1KG+0.5KG
    Water shortage protection value  ≤H*0.1KG
    Immersible pump automatic control
    The position of device
    Height
    the highest outlet of water
    the surface location of water
    The Upper Value=(The Max. Pressure of Pump-H )*0.1KG-0.5KG
    The lower value=H1*0.1KG+0.5KG
    Water shortage protection value  ≤H1*0.1KG
    REAR THE CODE
    CODE
    MEANING
    HOW TO USE
    H2.9
    Upper value,stop 2.9KG
    You can set it as instruction
    L1.5
    Lower Value,stop 1.5KG
    You can set it as instruction
    F0.2
    Water shortage protection  0.2KG
    You can set it as instruction
    E-F
    Water shortage protection
    Press ON/OFF to restart or waiting for restart automatically
    E-H
    Error,over the pressure range or the sensor damaged
    Check the pressure source
    The wiring
    Please see the back of the WPC-10 pressure control, the left is Chinese word "power", you can supply 220Vac from here, the right is Chinese word "motor", please connect it with the pump 220Vac supply terminal.
    Description Of Using
    Water Supply from Upstairs to Downstairs
    Immersible pump automatic control
    The Upper Value=
    The Upper Value=
    The Max. Pressure of Pump -0.5KG
    (The Max. Pressure of Pump-H )*0.1KG-0.5KG
    The lower value=0.5KG
    The lower value=H1*0.1KG+0.5KG
    Water shortage protection value=0.2KG
    Water shortage protection value≤H1*0.1KG
    Water Supply from Downstairs to Upstairs
    The Upper Value=The Max. Pressure of Pump-0.5KG
    The lower value=H*0.1KG+0.5KG
    Water shortage protection value
    ≤H*0.1KG
    Technical Parameter
    Pressure Range
    0-10KG f/CM
    Voltage Supply
    220Vac(You require a 3 phase AC contactor with 380V pump)
    Connection
    G1/2(Standard),it also can be customized
    Overload Capacity
    220V,10A; Pump(≤1.5KW) can be started directly
    Read The
    C
    ode
    C
    ode
    M
    eaning
    H
    ow
    T
    o
    U
    se
    H2.9
    Upper value,stop2.9KG
    You can set it as instruction
    L1.5
    Lower Value,stop1.5KG
    You can set it as instruction
    F0.2
    Water shortage protection  0.2KG
    You can set it as instruction
    E-F
    Water shortage protection
    Press ON/OFF to restart or waiting for restart automatically
    E-H
    Error,over the pressure range
    Check the pressure source